Blogs

16
Oct 2023

Ensuring Quality Revolutionizing Coffee Packaging with Precision Control

Ensuring Quality Revolutionizing Coffee Packaging with Precision Control

In the early days, coffee was often packaged in simple sacks or bags made from natural materials, such as burlap or hemp. These materials were not very airtight, so they could not keep coffee fresh for long periods of time. Vacuum sealed packaging was invented during the 1900s. This packaging removes all of the air from the packaging, which helps to keep coffee fresh for an extended period of time. Vacuum sealed packaging is also lightweight and relatively inexpensive, so it quickly became the most popular type of coffee packaging.

In recent years, there has been a growing trend towards more sustainable coffee packaging. This trend is driven by concerns about the environmental impact of traditional coffee packaging materials, such as plastic and tin.

Overview of Coffee Packaging

Coffee packaging refers to the process of packaging and presenting coffee beans or ground coffee for distribution, sale, and consumption. Coffee packaging serves several important purposes, including preserving the freshness and flavor of the coffee, protecting it from external elements such as light, moisture, and oxygen, and providing information to consumers.

Coffee packaging plays a crucial role in ensuring that coffee reaches consumers in optimal condition, with its flavor and aroma preserved. It also serves as a means of communication between coffee producers and consumers, conveying information about the coffee's characteristics and the values of the company that produces it.

Integrity testing of coffee packaging ensures that the packaging is free of leaks and defects that could compromise the quality of the coffee. This is important to do, as leaks can allow oxygen, moisture, and light to enter the packaging, which can all degrade the flavor of the coffee.

Here are some of the benefits of integrity testing for coffee packaging:

  • It can help prevent coffee from going stale or developing off-flavors.
  • It can help protect coffee from contamination.
  • It can help ensure that coffee meets quality standards.
  • It can help reduce product recalls.
  • It can help improve customer satisfaction.

Quality Testing Using Vacuum Decay Technology

Vacuum decay technology is a non-destructive method for testing the integrity of coffee packaging. It is a Container Closure Integrity Test (CCIT) method with a proven capability of non-destructively testing packaging at the production line with unmatched reliability and sensitivity. Non-destructive testing not only allows a greater understanding of package quality, but also reduces waste as compared to destructive test methods. Waste reduction, in turn, results in a higher return on investment and brings operations closer to green initiatives.

Vacuum decay technology operates by placing sample packages in a closely fitting evacuation test chamber, which is equipped with an external vacuum source. Single or dual vacuum transducer technology is used to monitor the test chamber for both the level of vacuum as well as the change in vacuum over a predetermined test time. The changes in absolute and differential vacuum indicate the presence of leaks and defects within the package. VeriPac series is a practical alternative to destructive test methods and can precisely detect leaks as small as 5 microns, identifying process issues before they become critical, avoiding catastrophic quality deviations.

Benefits of Vacuum Decay Test System

  • Non-destructive technology.
  • ASTM Test Method F2338, FDA Consensus Standard and referenced in USP 1207 Guidelines.
  • Accurate, repeatable results.
  • Pass/fail results backed by quantitative test data.
  • Completely tool-less with no changeover to test different packaging formats.
  • Identifies which cavity is defective.
  • Eliminates destructive, subjective testing methods.

Vacuum decay technology is a valuable tool for ensuring the quality of coffee packaging. It can help prevent coffee from going stale or developing off-flavors. It can also help protect coffee from contamination. If you are a coffee roaster or retailer, integrity testing of coffee packaging is an important quality control measure that you should implement.

Readmore...
vacuum decay technology, vacuum decay leak testing, package integrity testing, cci testing, ccit
52
22
Sep 2022

Industrial Applications of Vacuum Decay Technology

Industrial Applications of Vacuum Decay Technology

Vacuum Decay is a non-destructive method for testing the integrity of container closures for package integrity and leak path detection. The technology provides quantitative, deterministic, and reliable test results to assure package integrity in comparison to manual inspection and other non-deterministic test techniques. The vast range of package types that may be accommodated by Vacuum Decay technology includes filled and sealed rigid, semi-rigid, and flexible packaging consisting of non-porous or porous materials.

Vacuum Decay Technology

Vacuum Decay is one of the most efficient and accurate vacuum-based leak detection methods. The method operates by placing the package within a properly outfitted evacuation test chamber that contains an external vacuum source. To detect any deviations from a predetermined targeted vacuum level, the vacuum levels are continually monitored. If there is a defect in the packaging, air or liquid will leak into the chamber from the package and cause a change in pressure. On the other hand, non-defective packages do not leak any pressure into the chamber, maintaining the chamber vacuum level constant. The test cycle is quick, non-invasive, and non-destructive to both the product and the container. The Vacuum decay system can detect both major and minor defects, regardless of where they are located. The system has various applications in the field of pharmaceuticals and medical devices.

Applications of Vacuum Decay Technology in Various Industries

  • Pharmaceutical
  • Pharmaceutical products are a range of substances used for treating, diagnosing, or changing organic processes to help the management of public health. Pharmaceutical products are tested to make sure they adhere to strict safety and quality requirements. Previously, pharmaceutical packaging was only subjected to sterility testing. However, the United States has recognized that sterility testing alone is not sufficient to maintain the integrity of pharma products. FDA (Food and Drug Administration) has published guidance related to pharma industry on submission of documentation for sterilization process evaluation in human and veterinary drug products.

    Container closure integrity (CCI) testing is a non-destructive package inspection technology for finding leaks and avoiding potential contamination. A test like this is necessary since any defect in the container might allow foreign particles to enter the product and thereby reduce its shelf life. Since it impacts both the product and the patient, a manufacturer places high priority on implementing the proper container closure system. Thus, the relevance of container closure integrity testing in the pharmaceutical industry has increased substantially over time. Vacuum Decay and MicroCurrent HVLD are the most chosen technologies for testing pharmaceuticals.

  • Medical Device
  • Maintaining medical device package integrity is essential to make sure the product is delivered to the end user unharmed. Medical device packaging and delivery options range from rigid non-porous containers to flexible porous packaging. Every packaging format has a different set of characteristics and requirements, so choosing the right inspection technique requires a thorough approach. Package challenges have risen along with packaging format and material innovations. Among all medical equipment, Class III devices produce the greatest risk to maintaining package integrity. These implanted devices preserve or maintain life. Pacemakers, cardiovascular stents, respiratory ventilators, and breast implants are a few examples of Class III medical devices. Since these devices are inserted into human bodies directly, even a small packaging defect puts patient’s safety at risk. Therefore, it is essential to evaluate the container closure integrity of medical devices.

Vacuum Decay Technology Benefits

  • Non-destructive, non-subjective and does not require sample preparation.
  • Detection of defects down to 0.01 cc/min.
  • Results show that they are more accurate than dye ingress.
  • Quantitative, deterministic testing technique.
  • Supports initiatives for waste reduction and sustainable packaging.
  • ASTM test method and FDA recognized standard.

When determining the integrity of pharmaceutical and medical devices, Vacuum decay leak testing is the best non-destructive option. The test measurement generates a reliable and accurate quantitative result, as well as a pass or fail decision. The FDA recognizes the standard Vacuum Decay leak test technique (ASTM F2338) as a consensus standard for evaluating container closure integrity (CCI). The test technique is referenced in the United States Pharmacopeia Chapter on CCI (USP Chapter 1207) and listed in ISO 11607.

Readmore...
container closure integrity testing, container closure integrity, cci testing, vacuum decay leak testing, vacuum decay technology
46
16
Nov 2021

Vacuum Decay Technology for Quality Control Assurance of Parenteral Products

Vacuum Decay Technology for Quality Control Assurance of Parenteral Products

A significant challenge faced by the pharmaceutical industry is insuring the container closure integrity of parenteral products. Therefore, maintaining the quality of parenteral products is critical in order to make sure they are actually sterile and safe for delivery to patients. Parenteral products are often packaged in a variety of formats. Liquid-filled containers, such as ampoules, syringes, and vials are the most prevalent forms. Microbial infection, exposure to gases, and water vapor can all lead to product degradation if the packaging is breached. Pharmaceutical products that save lives might lose their effectiveness or even cause adverse effects. As a result, container closure integrity is an important factor of the lifetime of a sterile pharmaceutical product.

Ensuring quality control with Vacuum decay technology

Vacuum decay is a test technique for determining closed container integrity (CCI) for high-risk packaging applications that provides quantitative and deterministic quality assurance with rapid, consistent, and reliable test results. The Vacuum decay method provides non-destructive and non-invasive leak detection in hermetically sealed containers. This is actually a simple test method and it tests container integrity using basic physical characteristics. It entails drawing vacuum on a package inside a test chamber and checking for any deterioration in the vacuum level, which would indicate a leak. As a non-destructive alternative to the water bath leak test, the approach has gained popularity. It saves money by not wasting items during the leak test.

This technique is applicable to a wide range of packaging formats. The Food and Drug Administration (FDA) has designated the standard vacuum decay leak test technique (ASTM F2338) as a consensus standard for container closure integrity testing. The test technique is mentioned in the United States Pharmacopeia Chapter on CCI (USP Chapter 1207) and is listed in ISO 11607.  It may be used to evaluate rigid or flexible packaging, as well as plastic, glass, or metal containers, making it useful in the pharmaceutical and food and beverage sectors.

Benefits of using Vacuum decay technology

  • Non-destructive, non-invasive, no sample preparation
  • Cost effective with rapid return on investment
  • ASTM test method and FDA standard
  • Pass/fail results backed by quantitative test data
  • Capability to test multiple packages in a single test cycle
  • Non-subjective, accurate and repeatable results

CCIT.s.a are leading providers of various CCI test methods including Vacuum Decay, MicroCurrent HVLD, and Helium Leak Detection, manufactured by our affiliate PTI Inspection Systems in the United States. We specialize in test method development for all container closure integrity of pharmaceuticals, medical device and nutritional products and package quality testing projects. Our aim is to provide customers with deterministic non-destructive technologies for container closure integrity and then provide full support in the complete implementation of CCI systems.

Readmore...
container closure integrity testing, container closure integrity, CCI test, seal integrity testing, vacuum decay technology
57
09
Aug 2021

Why use Vacuum Decay Technology for Ophthalmic Product Package Inspection

Why Use Vacuum Decay Technology For Ophthalmic Product Package Inspection

Ophthalmic products are sterile preparations that include contact lenses, specific surgical implants, eye gels, lotions, powders, parenteral medications, ophthalmic inserts, prefilled syringes, etc. These products are applied onto the exterior surface of the eye. Ophthalmic products are packaged by various pharmaceutical firms in various ways and in various materials. According to pharmaceutical production and packaging requirements, all ophthalmic products must pass a strict sterility test.

Plastic containers are used to package almost all commercially accessible ophthalmic products. Plastic bottles, which are mainly made of Low-Density Polyethylene (LDP), Polypropylene (PP), High-Density Polyethylene (HDPE), and other materials depending on the specific product demand, are the most widely used materials for packaging of ophthalmic products. These plastic packaging components, which include bottles, fittings, and closures, enjoy universal acceptability due to obvious advantages such as ease of use, reduced spillage, and little breakage. In the late 1940s, Alcon was the first business to produce these packaging components, known as "Drop-Trainers" for ophthalmic medications, and they quickly became the industry standard for packaging topical ophthalmic products.

VeriPac Vacuum Decay Technology

Vacuum decay is a testing process that has been validated over many years and has been improved by new technological advancements. The test method is straightforward in concept, and it tests container integrity using basic physical attributes. It includes drawing vacuum on a package inside a test chamber and checking for any degradation in the vacuum level, which would indicate a leak. It saves money by avoiding wasting product during a leak test, and many products provide a quick return on investment.

Leak testers from VeriPac attach to a test chamber that is specifically constructed to hold the package being evaluated. The package is then placed inside the vacuum-sealed test chamber. The test chamber is monitored for both the level of vacuum and the change in vacuum over a defined test time using single or dual vacuum transducer technology. The presence of leaks and faults within the package is indicated by variations in absolute and differential vacuum. A test's sensitivity is determined by the package design, the package test fixture, and crucial time and pressure test parameters. Manual or fully automated testing systems are available. For QA/QC statistical process control, this inspection method is appropriate for laboratory offline testing and production applications. The test cycle is quick, non-invasive, and non-destructive to both the product and the packaging.

The VeriPac 455 is a non-destructing and quantitative inspection device that enables the very sensitive identification of empty and pre-filtered syringes, liquid filled and freezed vials, as well as other forms of liquid filled packaging, without any preparation of the sample. The VeriPac 455 is adequate to the challenge of testing these types of products, which necessitates the highest level of sensitivity, reproducibility, and accuracy.

Benefits of VeriPac 455

  • No sample preparation, non-destructive, and non-subjective
  • Highest level of sensitivity, repeatability and accuracy
  • Results have been shown to be superior to dye intrusion
  • Deterministic, quantitative test method
  • Supports zero-waste and sustainable packaging
  • ASTM test method and FDA standard
  • Capable of detecting leak rates as low as 0.01 cc/min
Readmore...
ophthalmic products, veripac 455, vacuum decay technology, ophthalmic product packing, ophthalmic product package inspection
91
23
Jul 2021

CCIT for Pharmaceutical Package Integrity

CCIT for Pharmaceutical Package Integrity

Over the last two decades, pharmaceutical industry has seen tremendous growth in the form of technological advancements and drug delivery system innovations. However, such innovations have increased quality assurance challenges for drug manufactures. For this reason, drug product manufacturers give at most importance to their quality control procedures as well as package integrity tests. All packaging forms, whether pouches constructed of porous or nonporous material, rigid thermoformed trays with Tyvek or film lids, bottles with induction-welded seals, or blister packs, need verification that their sterile-barrier characteristics are not compromised. Previously, only sterility testing was conducted on pharmaceutical packaging. However, when it was realized that sterility testing alone is not sufficient to hold the integrity of the medical products, the US FDA published Guidance for Industry for Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products. This emphasized the importance of verification of microbial barrier properties of a pharmaceutical product package (i.e., CCI).

Relevance of CCIT in pharmaceutical package testing

Container Closure Integrity Testing is an assay to evaluate whether container closure systems can maintain sterile barriers against potential damage. Even a minute defect in the container can cause external elements to enter the product, thereby reducing its shelf life. Common threats that can pass through a defected container closure system include microorganisms, reactive gases, and other substances. Considering the ability of such threat to deteriorate product quality, undertaking appropriate CCI tests are beyond crucial. However, it should be noted that CCI is not a one-time process, rather an integral and comprehensive approach. It is evaluated throughout the manufacturing lifecycle of a sterile drug product -from primary package development until the products are dispatched.

Container closure systems are made up of primary packaging components and secondary packaging components. Components like vials or syringes that are in direct contact with the product are called primary packaging components. Although there are multiple CCI techniques available in the market today, regulatory guidelines have broadly classified methods into probabilistic and deterministic test methods. Under a probabilistic test method, results are generated through a series of events, each with a respective probability distribution. Thus, the accuracy of the results cannot be assured. In contrast to a probabilistic method, deterministic test methods assure quantitative results with higher level of accuracy and reliability. The United States Pharmacopeia in 2016 issued new guidelines stating that deterministic methods are preferred over probabilistic test methods. Container closure integrity testing can be performed in many different ways. All the testing methods have pros and cons. Given below is a list of non-destructive Container Closure Integrity test methods:

  • Airborne Ultrasound technology
  • Vacuum Decay technology
  • Microcurrent HVLD technology
  • Helium Leak Detection
  • Pressure Decay leak testing
  • Force Decay leak testing
Readmore...
pharmaceutical package testing, container closure integrity testing, Vacuum Decay Technology, Airborne Ultrasound technology
52
15
Jul 2021

Vacuum Decay Technology Raising Standards for Pharmaceutical Package Testing

Vacuum Decay Technology Raising Standards for Pharmaceutical Package Testing

Right from clinical trials to drug packaging, all aspects for pharmaceutical industry are subject to strict quality control regulations. The process of selecting and validating appropriate packaging for pharmaceutical products takes a significant effort. Pharmaceutical package testing is conducted to ensure the suitability of drug packaging for its intended use. It included all components containing the product, even if they are in direct contact with the drug or not. As such, containers should be capable of retaining the healing properties of the drug product throughout its shelf life or until it is administered. Even a minute breach in container closure integrity can compromise the safety and effectiveness of the drug product. This realization has prompted pharmaceutical product manufacturers to conduct appropriate container closure integrity tests to ensure product sterility throughout its lifecycle.

Why use Vacuum Decay technology for pharmaceutical package testing?

PTI’s Vacuum Decay technology is a non-destructive container closure integrity testing method, capable of evaluating both liquid and air-filled containers and detecting defects as small as below 1 micron. Non-destructive testing provides a greater understanding of package quality while also reducing waste. Waste reduction delivers a fast return on investment and brings operations closer to green initiatives. Proven to be the most practical and sensitive vacuum-based leak test method, Vacuum Decay technology is an ASTM test method, FDA consensus standard, eliminating false positives and subjective results associated with manual visual inspection. Vacuum Decay technology can identify leaks in sealed rigid, semi-rigid and flexible packaging made of non-porous or porous materials. It provides reliable, accurate and repeatable test results that ensure deterministic package testing and leak detection.

Vacuum Decay technology operates by placing sample packages in a closely fitting evacuation test chamber, which is equipped with an external vacuum source. Single or dual vacuum transducer technology is used to monitor the test chamber for both the level of vacuum as well as the change in vacuum over a predetermined test time. The changes in absolute and differential vacuum indicate the presence of leaks and defects within the package. Vacuum Decay technology is a practical alternative and significant improvement to destructive test methods and can precisely detect leaks as small as 5 microns, identifying process issues before they become critical, avoiding catastrophic quality deviations.

Benefits of PTI’s Vacuum Decay Test System

  • Better process control - reliable and sensitive leak detection of quality critical defects.
  • The advantage of test results that are both qualitative (pass/fail) and quantitative (Statistical data with each test result).
  • Repeatable test results demonstrate the reliability of the instrument and test data.
  • Cost savings - Eliminates product loss, waste and mess of both packaging and coffee that results from using destructive testing methods
  • Using a non-destructive leak test method allows an increase in the number of products samples tested.
  • Rapid test cycle and minimal training required to operate tester.
  • Rapid ROI due to substantial cost savings and elimination of product loss.
Readmore...
container closure integrity testing, pharmaceutical package testing, vacuum decay technology
53
02
Jul 2021

How have VeriPac Systems Raised Standards for Container Closure Integrity Testing?

How have VeriPac Systems Raised Standards for Container Closure Integrity Testing

What is Container Closure Integrity Testing?

Container Closure Integrity Testing can be understood as a leak detection test conducted using non-destructive package inspection systems to ensure product stability throughout its shelf life. CCIT plays a major part in ensuring that the products are free from possible contamination. While there are multiple ways to conduct a CCI test, it can be broadly classified into probabilistic and deterministic test methods. Traditional test methods like bubble test, dye ingress and microbial challenge by immersion come under probabilistic test methods. However, upon realizing that such tests lacked accuracy and reliability, The United States Pharmacopeia released guidelines in 2016 stating that deterministic methods ae preferred over probabilistic test methods. Vacuum Decay technology and Airborne Ultrasound technology are among the most preferred deterministic test methods.

VeriPac Test Systems for Effective CCI Testing

The VeriPac test methods are non-destructive, non-invasive inspection system for CCI and package integrity testing. They utilize the ASTM approved patented vacuum decay leak test method recognized by the FDA as a consensus standard for package integrity testing.

This ASTM method was developed using VeriPac leak test instruments and has proven its capabilities under GMP regulatory guidelines. Applications for VeriPac technology include stability studies, clinical trials, quality assurance testing and statistical process control (SPC). VeriPac testers feature the patented PERMA-Vac manifold system and dynamic test modes that provide the ability to test a wide range of package formats. Leak detection of high-risk applications requires the highest level of test measurement reliability. The VeriPac series have redefined the reliability and accuracy of test measurement systems.

How do Veripac Test systems Operate?

VeriPac leak testers connect to a test chamber that is specially designed to contain the package to be tested. The package is placed inside the test chamber to which vacuum is applied. The single or dual vacuum transducer technology is used to monitor the test chamber for both the level of vacuum as well as the change in vacuum over a predetermined test time. The changes in absolute and differential vacuum indicate the presence of leaks and defects within the package. Test systems can be designed for manual or automatic operation. This inspection method is suitable for laboratory offline testing and production applications for QA/QC statistical process control. The test cycle takes only a few seconds, is non-invasive and non-destructive to both product and package, making it an ideal choice for CCI inspection across industries.

Inspection Criteria

  • Seal quality testing of entire container or package
  • Measures and verifies container closure system integrity
  • Tests for gas leaks for dry products (lyophilized vials, powder filled)
  • Tests for liquid leaks (liquid filled vials, pre-filled syringes)
Readmore...
seal quality inspection, vacuum decay technology, ccit, container closure integrity
59
14
Jun 2021

VeriPac UBV for Blister Package Inspection

  VeriPac UBV for Blister Package Inspection

Blister packs are popular packaging options for pharmaceuticals and consumer goods. A wide range of pharmaceutical products are packed in blister packs, ranging from capsules and tablets to high-risk hormone-based drugs and steroidal treatments. Commonly made of thermoformed plastic, these are quite useful in guarding products against external factors like heat, moisture and humidity.

However, concerns over integrity of blister packaging have increased over the years. Even a minute breach in the packaging can result in compromised package integrity. Hence, pharmaceutical manufacturers concerned about quality and shelf life of their products make Container Closure Integrity testing a crucial part of their manufacturing process. There are several methods available to test blister packs, and each has its own merits and demerits. For instance, the most common method to test blister packs remain dye ingress. However, this method is subjective, probabilistic and lacked accuracy in test results. This encouraged manufacturers to use non-destructive CCI test methods, that were accurate and produced quantitative results with measurable result data.

Blister Package Inspection with VeriPac UBV Technology

The VeriPac UBV Leak Detection System is a deterministic, non-destructive technology designed specifically for multi-cavity blister packs. The VeriPac UBV utilizes volumetric imaging under vacuum to detect the presence and location of leaks. It is a rapid test requiring no changeover or sample preparation. Operators simply input the number of blister cavities, place the blister pack on the inspection plate and press the START button. Within seconds, the operator sees a definitive pass/fail result, along with a volumetric measurement reading. The location of the defective cavity is presented to the operator with an image of the tested package. The intuitive and simple method makes it a practical solution giving rapid feedback to production line operators.

The UBV technology can provide rapid detection of defects as small as 10 microns with a fast test time, averaging 10-30 seconds depending on blister cavity volume. Test system requires no tools or test parameter changes for different blister formats. This technology is particularly advantageous for small to tiny blister cavities that are notoriously difficult to detect with a standard Vacuum Decay technology due to the very low headspace.

Technology Overview

Under this method, the sample is first placed inside the hinged test chamber. After pressing the start button, vacuum is pulled to a defined level. The blisters expand under vacuum, driving air out of the blister through any leaks present. If there is a leak in the blister, the air escapes into the chamber leaving a collapsed blister package. During the dynamic vacuum test sequence, a volumetric measurement reading is taken which determines which blister cavities are defective.

Benefits of VeriPac UBV Technology

  • Non-destructive technology
  • Accurate and repeatable results
  • Pass/fail results backed by quantitative test data
  • Completely tool-less
  • No changeover to test different blister formats
  • Identifies which cavity is defective
  • Eliminates destructive, subjective testing methods
Readmore...
container closure integrity, CCI, Vacuum Decay Technology, blister package testing
47
07
Jun 2021

Package Integrity Testing - The Next Big Technologies You Should Know

Package Integrity Testing The Next Big Technologies You Should Know

We all know that the primary function of any package is storing, handling & protecting the product. So, what is package integrity? Package integrity is defined as a package’s ability to protect its contents from potential hazards that include various physical, microbial & chemical factors. Its usefulness may have many nuances depending on the products & content. But industries like pharmaceutical, nutrition & medical device, deal with lifesaving & sustaining products that are shipped across the globe. Any discontinuity in the package can result in the contamination of the product making a life-saving product into a life-threatening one. Therefore, package integrity is imperative to ensure the safety of the products at the time of use.

The selection of the appropriate package inspection method is essential to maintain the quality standards that the regulatory bodies stand by today. Since 2016, the United States Pharmacopeia (USP) released guidance encouraging the use of deterministic, reliable test methods. Package leak test methods offered by CCIT s.a. are all deterministic, non-destructive, quantitative test methods with a specific on the reliability of the test result to assure integrity at the highest level.

VeriPac Vacuum Decay Technology

Vacuum decay is validated as one of the most reliable & sensitive vacuum-based leak detection methods that give quantitative & reproducible results with a pass or fail determination. PTI’s VeriPac inspection method is based on vacuum decay technology. It is one of the most ideal non-destructive container closure integrity testing solutions for different types of package formats that include parenteral packaging and other types of flexible and semi-flexible package formats. This method is non-invasive, non-subjective & requires no sample preparation. VeriPac 400 series can be used in various applications like stability studies, clinical trials, quality assurance testing and production statistical process control.

With PERMA-VAC, PTI redefined the vacuum-based leak detection method and addresses vacuum decay leak detection at the very core of physical test measurement & maximizing the SNR between good and defective samples.

Microcurrent HVLD

PTI has revolutionized the conventional HVLD method with the new HVLDmc – MicroCurrent HVLD, a highly sensitive leak detection method for all Parenteral and Biologic Products. The new E-scan 655 Microcurrent HVLD system exposes the product and environment to less than 5% of the voltage than conventional HVLD solutions. Referenced in USP <1207>, PTI’s HVLDmc has proven to be a highly sensitive leak detection method for applications like pre-filled syringes, vials, cartridges, ampoules, BFS, bottles, pouches.

Airborne Ultrasound

PTI’s proprietary Airborne Ultrasound technology is one of the most reliable seal quality inspection methods that characterize the overall quality and uniformity of the seal. This technology can be integrated for 100% online leak detection of pouch seals. Airborne ultrasound can be used for many material types such as Tyvek ®, paper, foil, film, aluminum, plastic & poly. This technology is referenced in the new USP <1207> Chapter guidance as a deterministic test method for seal quality testing. It is also an ASTM Test Method and FDA-recognized standard for seal quality testing.

Automated Inline Solutions

CCIT provides automated package inspection solutions across all PTI technology platforms – Vacuum Decay, Airborne Ultrasound and MicroCurrent HVLD. The Automated Systems are designed using PTI’s VeriPac, MicroCurrent HVLD and Airborne Ultrasound technologies for applications that include automated statistical process control (SPC) testing and 100% inline testing. The configurations are equipped with the capability of fully automated inspection with robotic pick and place. HVLDmc and Vacuum Decay overlap in capabilities, but more importantly encompass the full parenteral market range. The Airborne Ultrasound Technology for the 100% inline inspection of pouch seals has been an efficacious solution to verify final pouch seal quality.

Helium Leak Testing

Helium leak testing can be used for packaging tests quantitatively using helium as a tracer gas. Helium-based leak testing systems allow comparison between multiple packaging materials and forms production line settings and stability storage conditions, supporting the entire lifecycle. This method is also effective for various package types including cold form blister cards, foil pouches, parenteral vials, syringes, pre-filled syringes and unique medical devices.

The package systems of complex drug and biologic required to be stored at below -20°C, and needs storage and distribution environment that include dry ice (~-78.5°C), or even liquid nitrogen (~-200°C) can be quantitively and accurately tested using helium leak detection technology. This one technology has many applications for container closure integrity testing of pharmaceutical and medical device products.

Readmore...
package integrity testing, vacuum decay technology, cci. airborne ultrasound technology, helium leak testing
59
03
Jun 2021

Vacuum Decay Technology-A Novel Solution for Nutritional Packaging Inspection

Vacuum Decay Technology-A Novel Solution for Nutritional Packaging Inspection

In today's world, with the popularity of health products continuing to rise, manufacturers must ensure products are packed properly. Because of this reason, the universal health-wise regulation has set a fixed standard for nutritional products packaging process. This is for the elimination of defects happening due to innate chemical reactions within the nutritional products. Such defects can expose products to oxygen, moisture or bacteria- compromising its quality and reducing shelf life.

Nutritional products including dairy products and protein powders are mostly shelf stable in nature. The high fat content in dairy products including cream, butter and ghee is prone to deterioration in its storage process, causing auto-oxidative reactions. The defects in the dairy products can be eliminated through proper nutritional packaging inspection only. Similarly, protein-based powders including soy and casein are extensively used as energy sources. Inefficiencies in packaging of such products can have an adverse effect on consumer’s health. Therefore, conducting package integrity testing of nutritional products are vital to eliminate defects in packaging as well as possibility of product contamination.

Vacuum Decay Technology – The Ideal Nutritional Packaging Inspection Solution

Vacuum Decay technology is a deterministic Container Closure Integrity test method for evaluating quality of nutritional product packaging. The non-destructive testing method improves quality of packaging and reduces wastage compared to destructive test methods. Cost-effective non-destructive testing results in higher return on investments and ensures quality of products.

Vacuum Decay technology operates by placing sample packages in a closely fitting evacuation test chamber, with an external vacuum source. A single or dual vacuum transducer technology monitors the test chamber over a predetermined test period. The changes occurring in vacuum levels are analyzed to identify leaks and defects within the package. CCIT’s VeriPac series helps in detecting small leaks before it becomes critical in quality abbreviations.

Benefits of Vacuum Decay technology

  • Non-destructive package inspection technology
  • ASTM Test Method F2338, FDA Consensus Standard and referenced in USP 1207 Guidelines
  • Accurate, reliable and repeatable test results.
  • Pass/fail results backed by quantitative test data.
  • Completely tool-less with no changeover to test different packaging formats.
  • Eliminates the need for destructive, subjective testing methods.
Readmore...
container closure integrity testing methods, vacuum decay technology, package integrity testing, ccit
42

Archives

    Popular Blogs

    Tags

    Why use Vacuum Decay Technology for Ophthalmic Product Package Inspection

    Aug 09, 2021   |   91

    Vacuum Decay Technology allows testing to detect leaks in non-destructing hermetically sealed containers. Most sensitive vacuum based leak test method.

    Why Microcurrent HVLD is the most preferred CCI technique for Parenteral Product Leak Testing ?

    May 24, 2021   |   86

    Microcurrent HVLD is one of the most preferred container closure integrity testing method for Biological & Parenteral Product Leak Testing

    Package Integrity Testing of Flexible Packages Using VeriPac FLEX Series

    Feb 03, 2022   |   83

    VeriPac FLEX Series non-destructive package inspection systems are specially designed for dry-filled pouches and flexible packaging.

    Leak Testing Blister Packages Using OptiPac Technology

    Aug 16, 2023   |   83

    OptiPac One-Touch Tool-less system is a deterministic technique designed for non-destructive Container Closure Integrity Testing of (CCIT) blister packages.

    How VeriPac 355 Ensures Quality and Integrity of Pharmaceutical Packages?

    Feb 28, 2022   |   82

    VeriPac 355 is a deterministic micro leak detection system for CCI, which is recognized by the FDA as a consensus standard of testing package integrity.
    Popup