A Simple Guide to CCIT Services

A Simple Guide to CCIT Services

The integrity of the container closure system is crucial for ensuring that all portions of pharmaceutical products stay sterile during transportation, storage, and usage. Product contamination occurs as a result of leaking containers or closures. A non-destructive packaging inspection technology used to keep an aseptic barrier against possible contaminants is called Container Closure Integrity Testing (CCIT), commonly known as leak detection. The sterility and product quality of sterile final pharmaceutical and biological products should be maintained throughout their shelf life using container closure systems.

Various CCI Services

For testing the integrity of many package formats, CCIT offers expertise for the application of the best deterministic inspection technologies and test methodologies.

Feasibility Studies for Testing Package Quality

The first stage in evaluating and determining the optimal CCI technology and test technique for a certain application is to conduct an experimental or a more extensive feasibility study. To evaluate if a proposed CCI solution works and establish optimal test circumstances and Limit of Detection (LoD) is the goal of a feasibility study. CCIT’s aim is to provide clients with deterministic package integrity test solutions and help them in the installation of comprehensive CCI systems. This process starts with a client's problem description and ends with a clear approach to ensuring container closure integrity. Feasibility studies by CCIT for package quality testing provide customers with a complete report on the quantitative test technique.

Test Method Development for CCI Testing

CCIT conducts feasibility studies and develops test methods for package quality testing, recommending test methods based on the customer's needs for a given package or container. CCIT's Test Method Development focuses on the package/product characteristics and the extent to which the package attributes must be challenged to ensure closure integrity. The Test Method Development comprises adjusting test parameter settings for a given test method, such as vacuum or high voltage, test cycle periods, and pass/fail criteria. The comprehensive report will include precise test processes and criteria, as well as test findings and leak rates that the customer may expect, along with conclusions and recommendations. Before being included in the final report, all of the worked-out test methods go through validation checks to verify that they are reproducible, accurate, specific, exact, and acceptable for their intended application.

Equipment and Application Support

CCIT offers analytical leak detection services as well as package integrity testing equipment and applications knowledge. We also provide demonstrations on equipment and application services.

At CCIT's laboratory, we have the following technological platforms:

  • VeriPac - Vacuum Decay applications
  • E-Scan - MicroCurrent High Voltage Leak Detection( MicroCurrent HVLD)
  • Seal-Scan®/Seal-Sensor - seal inspection through Airborne Ultrasound

CCIT also offers the following services:

  • Installation, training, and validation services for CCI applications
  • Calibration, technical assistance, and overall equipment maintenance
  • Navigating USP 1207/ASTM/ISO standards - CCIT and regulatory consultancy services

CCIT.s.a is Europe’s leading package testing equipment provider for pharmaceutical, medical device, food, and nutrition companies. We have expertise in Test Method Development & Feasibility Studies. We focus on non-destructive technologies like Vacuum Decay, MicroCurrent HVLD, Airborne Ultrasound, and Helium Leak Detection for package quality testing.

Readmore...
container closure integrity testing, packaging integrity testing, container closure integrity, cci technologies, ccit
60
20
Jan 2022

MicroCurrent HVLD for Testing the Integrity of Ampoules

MicroCurrent HVLD for Testing the Integrity of Ampoules

Pharmaceutical package integrity testing has always been an important aspect of the quality control and manufacturing process. Container Closure Integrity is critical for protecting the product throughout its lifespan until it is delivered to the patient. CCIT uses non-destructive inspection technologies for ensuring container closure integrity of vials, ampoules, syringes, cartridges, and auto-injectors.

Ampoules must be properly sealed since any crack or defect might contaminate the sterile substance inside. Microbial contamination, exposure to gases, water vapor, and solvent loss can all cause product degradation if there is any breach in the package. Hence, container closure integrity is an essential stage in the lifecycle of a sterile pharmaceutical product. Patients may be at risk if the container closure integrity is compromised. Drugs that are meant to save lives might lose their effectiveness or cause fatal side effects. CCI defects can cause oxidation, which can reduce a drug's potency and shelf life.

Integrity Testing of Ampoules using MicroCurrent HVLD

MicroCurrent HVLD technology detects leaks in nonporous, rigid, or flexible packaging such as ampoules that contains liquid products. This is a non-destructive High Voltage Leak Detection Technology that is highly effective across all parenteral products (vials, syringes, ampoules and BFS). The test technique detects pinholes, microcracks, stopper/plunger leaks, non-visible leaks under crimping, and many other defects by scanning a non-conductive container sealed with electrode probes. Any crack or other defect in the container can cause a resistance difference and a change in the current flow, which would indicate a breach. It is also possible to determine the approximate position of the defect.

When compared to conventional HVLD technologies, MicroCurrent HVLD uses around 50% less voltage and exposes the product and environment to less than 5% of the voltage. At high production speeds, this HVLD method may be simply transitioned from offline to 100 percent inline testing applications. It is a cost-effective online container closure testing solution that requires only minor infrastructure changes. This method is non-invasive and does not need sample preparation. For all parenteral and biologic products, MicroCurrent HVLD is one of the most effective CCI methods.

MicroCurrent HVLD Benefits

  • Effective in all parenteral preparations, even liquids with extremely low conductivity.
  • At high production speeds, inspection can be done both offline and online.
  • Non-destructive, non-invasive, and requires no sample preparation.
  • High level of accuracy and repeatability.
  • Deterministic method for parenteral liquid package inspection.
  • A robust technique for a variety of product classes and packaging forms with an estimated 3x Signal-Noise-Ratio.

Ampoules are such little glass bottles containing a sterile pharmaceutical liquid for parenteral administration. Microbes or other harmful pollutants may enter the ampoules through capillary pores or microscopic breaks, or the contents may leak to the outside. This may result in contamination of the sterile contents as well as a deterioration of the appearance of the package. MicroCurrent HVLD technology offered by CCIT can be applied to a variety of pharmaceutical packing formats including ampoules for testing integrity.

Readmore...
microcurrent hvld, package integrity, packaging integrity testing, container closure integrity, container closure integrity testing
58
18
Jan 2022

Package and Seal Integrity Testing Techniques for Nutritional Packaging Inspection

Package and Seal Integrity Testing Techniques for Nutritional Packaging Inspection

Testing the integrity of package seals helps ensure that nutritional packaging provides required product protection. Maintaining the reliability of package seals is critical for product quality and food safety. Airborne Ultrasound and Vacuum Decay technology can be used for testing package and seal integrity of nutritional packages. These CCI technologies produce quantitative, and repeatable results, due to their deterministic nature. The primary purpose of implementing these testing methods is to ensure the safety of consumers.

Overview of Nutritional Packaging Inspection

Nutritional packaging plays a significant role in securely delivering the product. The majority of nutritional products are shelf-stable in nature, therefore package performance is typically a concern. Chemical reactions occur naturally in all nutritional products. Any break in the nutritional packing might lead to the products deteriorating due to air, moisture, and microbial exposure. Fats and other nutrients for infants might become rancid and inactive. The quality and safety of the contents that reach the customer are determined by nutritional packaging.

Package and seal integrity techniques have great expertise in the packaging industry, which helps in inspecting nutritional packages in the most efficient method in order to preserve package and product quality. For the food and nutritional packaging industries, CCIT provides a variety of technologies and solutions. The two most common nutritional package inspection technologies are vacuum decay and airborne ultrasound. While vacuum decay is utilized for applications such as filled and sealed rigid containers, dry products in pouches, and flexible packaging. Retort pouch final seal inspection can be achieved using non-destructive with airborne ultrasound technology.

Technologies to Assure Package and Seal Integrity

Vacuum Decay Technology

Vacuum decay is a package test method for vacuum-based leak detection. It is considered one of the most practical and sensitive test methods used in nutritional package inspection. When compared to destructive test procedures, this technology not only provides for a better understanding of package quality but also minimizes waste. As a result of the waste reduction, the return on investment is higher, and the operation is closer to green initiatives.

The Vacuum Decay leak testing method operates by enclosing package samples in an evacuation test chamber with an external vacuum source. The test chamber is monitored for both the level of vacuum and the change in vacuum during a pre-defined test duration using single or dual vacuum transducer technology. The existence of leaks and defects within the package is indicated by variations in an absolute and differential vacuum. Test systems can be designed to be operated manually or fully automated.

Airborne Ultrasound Technology

Pouches are the common form of packaging for most nutritional products. Hence, it is necessary to ensure the package integrity of such pouches. Airborne Ultrasound is a non-destructive and non-invasive method of inspecting seal quality. In this method, ultrasound waves are permitted to pass through the package seal, causing sound waves to be reflected. The fluctuation in the reflected signal intensity is used to detect defects.

Airborne Ultrasound technology is available in both online and offline solution options. It has been proven to be one of the most successful non-destructive testing procedures for flexible package seals. According to ASTM F3004-13, this is the standard test technique for evaluating seal quality and integrity using airborne ultrasound. This method has high applicability in the food and nutrition industry.

Vacuum Decay technology and Airborne Ultrasound technology are both ASTM test methods and also FDA consensus standards for package integrity and seal quality inspection of nutritional products. An appropriate testing method for inspecting nutritional packages is selected based on the nature of the product and its package.

Readmore...
seal quality inspection, cci technologies, packaging integrity testing, vacuum decay leak testing, container closure integrity testing
77

Archives

    Popular Blogs

    Tags

    Why use Vacuum Decay Technology for Ophthalmic Product Package Inspection

    Aug 09, 2021   |   90

    Vacuum Decay Technology allows testing to detect leaks in non-destructing hermetically sealed containers. Most sensitive vacuum based leak test method.

    Why Microcurrent HVLD is the most preferred CCI technique for Parenteral Product Leak Testing ?

    May 24, 2021   |   85

    Microcurrent HVLD is one of the most preferred container closure integrity testing method for Biological & Parenteral Product Leak Testing

    Leak Testing Blister Packages Using OptiPac Technology

    Aug 16, 2023   |   83

    OptiPac One-Touch Tool-less system is a deterministic technique designed for non-destructive Container Closure Integrity Testing of (CCIT) blister packages.

    Package Integrity Testing of Flexible Packages Using VeriPac FLEX Series

    Feb 03, 2022   |   82

    VeriPac FLEX Series non-destructive package inspection systems are specially designed for dry-filled pouches and flexible packaging.

    How VeriPac 355 Ensures Quality and Integrity of Pharmaceutical Packages?

    Feb 28, 2022   |   81

    VeriPac 355 is a deterministic micro leak detection system for CCI, which is recognized by the FDA as a consensus standard of testing package integrity.